Released EMC D-PE-OE-23 Updated Questions PDF

D-PE-OE-23 Dumps and Practice Test (325 Exam Questions)

Q160. What is a requirement to operate GPUs in a Dell EMC PowerEdge R740 server?

 
 
 
 

Q161. A technician builds a bootable ISO with Repository Manager, and then mounts the ISO via the iDRAC virtual console. After the updates have completed, the technician reboots the server to apply the updates. When reviewing the updates, the technician determines NOT all updates were applied.
What is causing this issue?

 
 
 
 

Q162. What is required to use the iSM Automatic System Recovery feature?

 
 
 
 

Q163. A drive has failed in one of the two disk groups in a Dell PowerEdge server. The assigned hot spare did not replace the failed drive.
How should the RAID SET have been assigned to avoid this issue?

 
 
 
 

Q164. A technician is setting up a previously used server. Upon power up, the PERC alerts them to the presence of a foreign configuration. In the iDRAC storage section, the technician checks Foreign View.
The foreign array configuration is the same as the configuration needed for the new project.
What is a recommended way to prepare the disks for the new project?

 
 
 
 

Q165. What is used by the Lifecycle Controller to directly back up the server profile on a 14G Dell EMC PowerEdge server?

 
 
 
 

Q166. A technician is sent on-site to troubleshoot a server that halts during POST. The iDRAC System Event Log shows the following errors: A bus fatal error was detected on a component at bus 0 device 1 function
1 A bus fatal error was detected on a component at bus 1 device 0 function 0 CPU 1 has an internal error (IERR) The following system information is provided.

Which system component is the most likely cause?

 
 
 
 

Q167. You have been tasked with configuring a Dell EMC PowerEdge server to be a file server. The server operating system has been installed and there are 8 x 1TB drives that must be configured.
Which RAID configuration would provide the maximum usable space with maximum redundancy?

 
 
 
 

Q168. A technician wants to install a new version of OMSA onto a server that already has an existing version of OMSA.
What is required for this new installation?

 
 
 
 

Q169. A technician needs to install a PCIe NIC into a production server. Six of the seven PCI slots are already populated.
What does the technician need to verify before installing the PCIe NIC?

 
 
 
 

Q170. What does OBPAR allow on a PowerEdge MX750c?

 
 
 
 

Q171. What is the recommended option to use when applying firmware to a replaced part using the Lifecycle Controller?

 
 
 
 

Q172. Eight new servers have arrived at a datacenter. All use static IP addresses for iDRAC. The technician needs to enable these servers to contact the DHCP server on the network to obtain new IP addresses.
What method can the technician use to quickly switch to DHCP?

 
 
 
 

Q173. The operating system on a Dell PowerEdge R760xa fails to boot.
What iDRAC feature under the iDRAC UI Troubleshooting tab can be used to diagnose the issue?

 
 
 
 

Q174. A technician is configuring a PowerEdge R640 that has two PSUs. The rack in which it is being installed has two power distribution units (PDUs). No high power such as GPUs are required. The user wants as must redundancy protection as possible.
What is the best way to configure the PSUs?

 
 
 
 

Q175. Which tool allows an administrator to remotely back up a PowerEdge server configuration to streamline server deployments?

 
 
 
 

Q176. What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge
14G servers?

 
 
 
 

D-PE-OE-23 Exam Dumps Pass with Updated 2024 Certified Exam Questions: https://www.examdumpsvce.com/D-PE-OE-23-valid-exam-dumps.html

         